Product details


PRODUCT OVERVIEW


R200kW/400V/50Hz load bank is a resistance load bank developed and produced by our company. The load bank has reasonable structural design and makes full use of space layout. The appearance adopts two-color matching design. The cabinet frame adopts black frosted design and the cover plate adopts yellow frosted design. It is fashionable and beautiful. The function is controlled by local manual knob and equipped with local control of Siemens touch screen, In addition, customers can choose whether they need remote PC upper computer control.


PRODUCT PICTURE




APPLICATION SCENARIO



PARTIAL PARAMETERS



Note: all parameters are for reference only and can be customized

Product name

resistance load bank

Specifications

R200kW/400V/50Hz

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load step

According to customer needs

Load connection

Copper bar

Resistor

Each resistance element: insulation impedance DC1000V/100MΩ above

Withstand voltage ac 2000v for 5min

Resistance error of each resistance tube:±3%

Load control

Local manual control, local automatic control or remote automatic control can be selected

Loading accuracy

Less than or equal to 3%

Three phase balance

Unbalance degree less than or equal to 3%

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

TN-C,380V/50Hz

Cooling mode

Forced air cooling, side air outlet

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, etc

Load expansion

Parallel expansion of multiple load containers

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Color

Customized

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa


MORE SPECIFICATIONS



Note: all parameters are for reference only and can be customized

Power(kW)

Voltage(kV)

Frequency(Hz)

Size(mm,L*W*H)

Weight(Kg)

Low voltage

100

0.4

50

1100*900*1000

320

200

0.4

50

1350*1100*1100

450

300

0.4

50

1500*1200*1200

650

400

0.4

50

1700*1500*1500

830

500

0.4

50

1700*1600*1600

950

600

0.4

50

1800*1600*1600

1150

800

0.4

50

1900*1800*1700

1900

1000

0.4

50

2300*1700*2100

2100

1200

0.4

50

2500*1800*2200

2300

1500

0.4

50

2500*1860*2300

2600

1800

0.4

50

3000*2000*2300

4000

2000

0.4

50

3000*2000*2300

5000

2500

0.4

50

4000*2438*2500

6000

3000

0.4

50

6000*2438*2500

7000

Medium voltage

1000

6/10.5

50/60

3000*2438*2500

3500

1200

6/10.5

50/60

4000*2438*2500

3900

1500

6/10.5

50/60

4000*2438*2500

4500

1600

6/10.5

50/60

5000*2438*2500

5000

1800

6/10.5

50/60

5000*2438*2500

6500

2000

6/10.5

50/60

6000*2438*2500

7500

2200

6/10.5

50/60

6000*2438*2500

8000

2500

6/10.5

50/60

6000*2438*2500

10000

3000

6/10.5

50/60

7000*2438*2500

12000

4000

6/10.5

50/60

8000*2438*2500

14000

5000

6/10.5

50/60

9000*2438*2500

15000

6000

6/10.5

50/60

12000*2438*2500

16000

7000

6/10.5

50/60

12000*2438*2500

17000

8000

6/10.5

50/60

12000*2438*2500

18000


CONTROL AND DISPLAY


(1)Control mode selection: local manual, local touch screen or remote PC can be selected to control the load.

(2)Local manual control: the load is equipped with a local control panel and divided into several power gears, which can control the load through the switch.

(3)Local touch screen control: automatically load and control the load through local touch screen software.

(4)Remote PC control: control the load through the data management software on the computer, realize all test functions, display, record and manage the test data, generate various curves, charts and test reports, and support printing.

(5)Interlock of control mode: the system is equipped with a control mode selection switch. After selecting any control mode, the operation through other modes will be invalid to avoid conflict caused by multiple operations.

(6)Local instrument display data: the three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency and other parameters can be displayed through the local measuring instrument, and the independent load circuit data can be displayed separately.


HONORARY QUALIFICATION


Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.



http://www.cnloadbank.com/

Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 
Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed